Vicom Plus presents:

CFD Modeling Service

Test the functionality of your data center’s cooling system as the load increases up to the design values.

This will help identify local overheating zones and clearly visualize potentially hazardous failure points in your data center’s operation.

Learn more

What is the result?

The result of CFD modeling should be a model of temperature and pressure variations in the computer room (three-dimensional).

Such a model will allow you to determine:

  • How the placement of future IT capacity will affect the cooling system’s ability to meet the needs of the computer room;

  • Modeling various failure scenarios by “turning off” components in the CFD model and analyzing whether the remaining cooling system will be able to support the IT load.

Beware of counterfeit low-quality CFD analysis.

Vicom Plus works exclusively with certified international CFD modeling specialists.

CFD will help you:

Test cooling strategies

Whether conventional CRAC precision air-conditioning systems or CRAH computer room air handlers. In-row or suspended cooling units, with or without economizers.

Optimize size and placement

Check the number, size, and placement of cooling systems to optimize cooling distribution, taking into account the size and shape of the room, other architectural features (such as columns), and power distribution.

Optimize cooling paths

Including raised-floor height, suspended/drop-ceiling height, and the size of ventilation ducts. As well as optimizing the placement of floor, ceiling, and duct grilles.

Test containment concepts

For example, hot- or cold-aisle containment systems.

Test configurations

Partial or full load. As a rule, Customers primarily choose to assess the existing situation in an operating data center in terms of fault tolerance, as well as various subsequent capacity growth scenarios.

Test configurations

Backup cooling. Optimize energy efficiency. Assess the impact of standard cable layouts and much more.

Advantages of the “6SigmaRoom” Modeling Software

Software and Computing Complex "6SigmaRoom" by FutureFacilities is designed to model thermal processes in data centers using computational fluid dynamics (CFD) with the finite element method and subsequent solution, generation, and analysis of the results.


When assessing the condition of a data center cooling system

it is important to rely on globally recognized and authoritative sources of information. The most critical parameter for cooling IT equipment is the temperature of the supplied air. Overall, the primary task of a cooling system is to maintain the specified temperature and humidity levels.

One of the most widely recognized sources of such requirements is the American Society ASHRAE, specifically its Technical Document 9.9.

When interpreting the results of this study, the authors rely on a 2015 document in which the recommended supply air temperature range is 18...27 °C for equipment class A1 used in data centers.